Fluoroscopy

TOR IQ II

Special phantom for tests as per AERB QA format for Radiography and Fluoroscopy applications which suffices the requirements of:

Radiation and Optical Field Alignment Test Tool

Beam Alignment Test Tool

Low Contrast Resolution Test Tool

Focal Spot Test Tool

High Contrast Resolution Test Tool

Other tests:

Dynamic Range

Geometric Distortion

Noise/Uniformity

Artefacts

TOR 18FG

TOR 18FG is a fluoroscopy phantom, which enables the following checks to be made:

Monitor brightness and contrast level adjustment (highlight and lowlight details)

Resolution limit (0.5 to 5.0 LP/mm)

Low-contrast large-detail detectability (18 details, 8mm diameter)

Low Contrast Resolution Test Tool

Circular Geometry (Lead Circle)

The TOR 18FG phantom is supplied in a protective case with
1 x copper filter 1.0mm x 150mm x 150mm

Motus Motion Platform

The Leeds – MOTUS motion platform is a compact programmable motion arm ideal for introducing motion to your quality assurance testing to overcome the limitations with static testing of dynamic systems, especially where complex image processing is applied.

Benefits

Dynamic image quality scoring

Digital subtraction image quality

Pixel shift testing

SFS Set

A set of test objects designed to be used quickly and easily on an annual / commissioning basis to provide an ongoing check of imaging performance, particularly those aspects which are most liable to deterioration. An ongoing record of these numbers will reveal any trend towards deterioration in imaging performance.

TO XR21

The TO XR21 phantom is designed to allow the user to check image quality in accordance with the NEMA XR21 standard.

Fluoro 4 & Fluoro 4-L

Leeds Test Objects – FLUORO-4 phantom is designed to check the image quality performance of digital and conventional fluoroscopy X-Ray systems.

TO CDRH

 TO CDRH Phantom enables quality assurance testing of Radiography / Fluoroscopy systems.

TO CDRH enables tests for:

Low-contrast resolution (Aluminium disc with 8 contrast discs)

High-contrast resolution (Copper mesh targets from 12 – 80 lines per inch)

TOR ABC

Beam Alignment Phantom

Used for Radiography or Fluoroscopy, enables the following checks to be made:

The correspondence of the light field with the effective radiation field

The determination of the position of the central beam

The central beam angle deviation from 90°, relative to the plane of the film/detector, is below a limit that beyond which the image quality would be adversely affected

FluoroMesh

An image quality phantom, designed to provide an ongoing check of the resolution of fluoroscopy systems by counting the number of mesh patterns resolved in the image.

CBCT-150

CBCT-150 phantom is used for constancy testing of CBCT and 3D-Fluoroscopy systems.

Fluoroscopy​ Step Wedge

11 Step Wedge for use with Fluoroscopy systems.

Material: Aluminium

Overall dimensions: 132 x 50 x 35mm

Steps 12mm long x 50mm wide

Step 1: 5mm high

Other Steps: 3mm high

PMMA/Cu Attenuator

A bonded PMMA and Copper attenuator consisting of 30mm PMMA and 1mm Cu.

25mm Aluminium Attenuator

Leeds Test Objects- Aluminium Patient-Equivalent Attenuator is designed for use when checking the image quality performance of general radiography systems.

21mm Aluminium Attenuator

Leeds Test Objects – 21mm Aluminium Patient-Equivalent Attenuator is designed for use when checking the image quality performance of general radiography systems.

Accugel Phantom

Specifications:

Lifelike Tactile feedback to simulate needle resistance and fix needle entry position

Compact with small footprint for easy deployment and storage

Durable and Reusable after multiple punctures

Varying target size and depth also, progressively challenge competency in speed and accuracy while permitting trainees to experience different magnitudes of needle deflection at respective depths

Realistic Tissue imaging with Excellent visibility, targets placed at various depths are made to give high visibility under imaging modalities

Body curvature design – to mimic human contour and standardize depth from multiple access angles